Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on |
Model Name/Number | TU5200 |
Range | EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 |
Type Of Analytical Instrument | Laboratory Laser Turbidimeter with RFID,ISO Version |
Material | ABS |
Weight | 2.4 kg |
Display | 7" WVGA (800 x 480) color TFT-LCD with touch screen |
Size | 195 mm x 409 mm x 278 mm |
I Deal In | New Only |
Response Time | Signal averaging off: 7 seconds Signal averaging on: 10 seconds (when averaging time is 5 seconds) |
Number Of Calibration Point | For Formazin and Stablcal: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom cal |
Recommended | DIN EN ISO 7027 |
Power | AC SOURCE |
No. Of Calibration Points | 6 |
Brand | HACK |
Temperature | 10 - 40 DegreeC |
Automatic Range Selection | YES |
Is It Waterproof | Non Waterproof |
Turbidity Range | EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 |
Meter Style | The TU5 Series employs a patented optical design that sees more of your sample than any other turbid |
Measurement Range | EPA: 0 - 700 NTU / FNU / TE/F / FTU 0 - 100 mg/L 0 - 175 EBC ISO: 0 - 1000 NTU / FNU / TE/F / FTU 0 |
Languages | ENGLISH |
Grade | CE compliant US FDA accession number: 1420493-000 EPA version,1420492-000 ISO version Complies with |
Accuracy | +-2 % plus 0.01 NTU from 0 - 40 NTU; +-10 % of reading from 40 - 1000 NTU based on Formazin primary st |
Color | GREY |
Light Source | Class 2 laser product,with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product,with embedded 85 |
Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L |
TU5200 Low Range Laser Turbidimeter with AutomaticCleaning and System CheckCat. No: LXV445.99.31122Make: Hach, U.S.A.Includes: TU5200sc Turbidimeter, Automatic Cleaning Unit,User Manual, Wall Mount, Vial Replacement Tool, Screw Set,Drying Cartridge, Flow Regulator, Service BracketTechnical Specification:Accuracy:±2% or 0.01 NTU from 0 - 40 NTU±10% of reading from 40 - 700 NTU based on Formazinprimary standardCable Length:1.6 m (5.25 ft), extendable up to 50 m (164 ft) forinstrument without accessoriesCalibration Method: For Formazin and Stablcal®:20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for fullrange Custom calibration for up to 6-point calibrationsCommunication: System CheckController: Sensor OnlyController Options: Sensor OnlyDimensions (H x W x D):249 mm x 268 mm x 190 mmEnclosure Rating: Electronic compartment IP55; all otherfunctional units IP65 with process head/ACM attached to theTU5300sc/TU5400sc instrumentFitting Type: Sample quick connector: 1⁄4-in. for 1⁄4-in. tubingInstrument: with cleaningLight Source: Class 2 laser product, with embedded 650 nm(EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm(ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21CFR 1040.10 in accordance with Laser Notice No. 50)Lower Limit of Detection (LOD):0.002 NTU
3,20,320.00 01 3,20,320.00
TERMS & CONDITIONS FOR INDIAN RUPEES01. Prices Ex-Works DELHI02. Packing & Forwarding Extra @ 3% on Ex-Works Price03. Freight & Insurance Extra @ 3% on Ex-Works Price04. GST Extra @18% Will be charged05. Delivery READY STOCK OTHERWISE 8-10WEEKScleared Purchase Order.06. Payment Terms 100% advance along with order07. Validity One Month08. AMP TEKNO SERVICES. (GST & PAN NO.) DETAILS ARE BELOWPROVISIONAL GST NO: 09AALFA2395P1ZQPAN NO: AALFA2395PThanking You,
Additional Information:
- Item Code: TU5200
- Production Capacity: 100
- Delivery Time: READY STOCK
- Packaging Details: NICE PACKING ASA Luran S 777K / RAL7000, TPE RESIN
Elastocon STK40, Thermoplastic Elastomer TPS-SEBS